2981745概述

Multi-application Modular System - PSR-SPP SeriesThis can be quickly and reliably assembled to form a tailor-made safety solution. To connect using TBUS correctly you will need one PSR-TBUS per module. For the last additional module use one PSR-TBUS-TP instead, this will close the feedback loop. The interface module is used for the connection of up to four safety sensors with NC/NO contacts to the safety relay PSR-SDC4, with screw connection. Quick system extension up to 10 modules, offering a safety system with up to 42 contacts Automatic identification of desired operating mode, no need to set switches or define parameters The system is based on a master relay PSR-SDC that monitors e-stops, guard doors interlock or non-contact and optical devices e.g. light curtains Safe cross-wiring with T-BUS renders the usual cross-wiring of supply voltage, enable signal and confirmation path redundant. Making commissioning and future expansion simple 24Vdc supply voltage Semiconductor output Depending on the wiring Safety category 2 or 4 can be maintained One or Two channel switches are used for control Note: The device has a rear interface for the DIN Rail connector T-BUS. Via this T-BUS interface extension devices PSR-URM4-B undelayed contacts and PSR-URD drop-out delay contacts can be controlled and monitored over one channel. These in combination form a T-BUS unit, the feedback path must be connected to the final right hand extension device see datasheet for more details or by using connection plug PSR-TBUS-TP ### 可配置安全继电器

Multi-application Modular System - PSR-SPP Series

This can be quickly and reliably assembled to form a tailor-made safety solution. To connect using TBUS correctly you will need one PSR-TBUS per module. For the last additional module use one PSR-TBUS-TP instead, this will close the feedback loop. The interface module is used for the connection of up to four safety sensors with NC/NO contacts to the safety relay PSR-SDC4, with screw connection.

Quick system extension up to 10 modules, offering a safety system with up to 42 contacts

Automatic identification of desired operating mode, no need to set switches or define parameters

The system is based on a master relay PSR-SDC that monitors e-stops, guard doors interlock or non-contact and optical devices e.g. light curtains

Safe cross-wiring with T-BUS renders the usual cross-wiring of supply voltage, enable signal and confirmation path redundant. Making commissioning and future expansion simple

24Vdc supply voltage

Semiconductor output

Depending on the wiring Safety category 2 or 4 can be maintained

One or Two channel switches are used for control

Note: The device has a rear interface for the DIN Rail connector T-BUS. Via this T-BUS interface extension devices PSR-URM4-B undelayed contacts and PSR-URD drop-out delay contacts can be controlled and monitored over one channel. These in combination form a T-BUS unit, the feedback path must be connected to the final right hand extension device see datasheet for more details or by using connection plug PSR-TBUS-TP

### 可配置安全继电器

2981745中文资料参数规格
技术参数

通道数 1

线圈电压 24 VDC

电源电压 24 VDC

封装参数

封装 -

外形尺寸

长度 112 mm

宽度 22.5 mm

高度 112 mm

封装 -

物理参数

触点材质 Silver Tin Oxide

其他

产品生命周期 Active

符合标准

RoHS标准 RoHS Compliant

含铅标准 Lead Free

数据手册

在线购买2981745
型号: 2981745
描述:Multi-application Modular System - PSR-SPP Series This can be quickly and reliably assembled to form a tailor-made safety solution. To connect using TBUS correctly you will need one PSR-TBUS per module. For the last additional module use one PSR-TBUS-TP instead, this will close the feedback loop. The interface module is used for the connection of up to four safety sensors with NC/NO contacts to the safety relay PSR-SDC4, with screw connection. Quick system extension up to 10 modules, offering a safety system with up to 42 contacts Automatic identification of desired operating mode, no need to set switches or define parameters The system is based on a master relay PSR-SDC that monitors e-stops, guard doors interlock or non-contact and optical devices e.g. light curtains Safe cross-wiring with T-BUS renders the usual cross-wiring of supply voltage, enable signal and confirmation path redundant. Making commissioning and future expansion simple 24Vdc supply voltage Semiconductor output Dep