Digital Termination Array 38Pin HTSSOP T/R
CLT01-38S4 adds to the existing current limiter family. Still focusing on power consumption savings, the whole series allows each customer to find the right solution.
The CLT01-38S4 is an octal input termination device with a high speed SPI output. Its maximum input data rate is 400 kbps while the output SPI speed is 6.25 MHz.
As in previous versions, robustness is a key feature of CLT01-38S4. The product is compliant with surge standards defined in IEC 61000-4-x.
It can run all types of sensor according to IEC 61131-2. Type 1 and 3 with a 2.35 mA limited current and type 2 using two inputs per sensor with the correct RREF.
**Key Features**
-
.
-
8-input circuit in common ground low side topology
-
.
-
Wide range input DC voltage VI : -30 V to 35 V
-
.
-
On state threshold: < 11 V with RI = 2.2 kΩ
-
.
-
Off state threshold: Iin > 1.5 mA or Vi > 5 V
-
.
-
Protected against -30 V reverse polarity
-
.
-
Typical ILIM = 2.1 to 2.6 mA adjustable current limiters
-
.
-
Tight current tolerance including temperature compensation: ±10%
-
.
-
Serial output with an SPI communication bus
-
.
-
Clock frequency up to 6.25 MHz
-
.
-
CPHA = CPOL = 0 bus master operation
-
.
-
Multi CLT operation in daisy chain connection
-
.
-
16-bit mode: 8 bits for data / 8 bits for control
-
.
-
Minimum capture time: 4 μs
-
.
-
Input data rate: 200 kbps/100 kHz
-
.
-
Minimum propagation transfer time: 7 μs
-
.
-
8-bit mode: 8 bits for data
-
.
-
Minimum capture time: 2.5 μs
-
.
-
Input data rate: 400 kbps/200 kHz
-
.
-
Minimum propagation transfer time: 4 μs
-
.
-
VCC = -0.3 to +35 V with RC = 2.2 kΩ
-
.
-
Ambient temperature range: -25 to +85°C
-
.
-
Digital inputs for programmable logic controller and decentralized I/O modules
-
.
-
Benefits
-
.
-
Enables input to meet type 1, 2 and 3 characteristics of IEC 61131-2 standard
-
.
-
Compatible operation with 2 wires proximity sensor according EN 60947-5-2 standard
-
.
-
Compact board with surface mount integration and reduced count of isolated couplers
-
.
-
Reduces the count of input-output of the bus controller circuit
-
.
-
Provides energy-less input LED visual status
-
.
-
Enhanced functional reliability
-
.
-
Built-in over voltage robustness and immune data transfer
-
.
-
Reduced dissipation: 78 mW max. per channel
-
.
-
Complies with following standards RI = 2.2 Ω, RC = 2.2 Ω, C = 33 nF:
-
.
-
Electrostatic discharge, IEC 61000-4-2:
-
.
-
±8 kV contact discharge
-
.
-
±15 kV air discharge
-
.
-
Electrical transient immunity IEC 61000-4-41:
-
.
-
FSCK= 6.25 MHz, ±3 kV
-
.
-
FSCK= 10 kHz, ±4 kV
-
.
-
Voltage surge IEC 61000-4-5
-
.
-
Input: ±15 kV
-
.
-
Power supply: ±2.5 kV