DNC-T2010-020

DNC-T2010-020概述

Dust Collector; 120VAC; 2VA Max.; 50/60Hz; -40 to degC

The DNC-T2003 through DNC-T2032 controls are output sequencers with an ad justable ON TIME, OFF TIME, and LAST OUTPUT. Upon application of power to the L1 and L2 terminals with the high pressure switch co ntacts c losed, the OFF TIME is initiated. At the end o f the preset OFF TIME, output 1will turn on for the preset ON TIME. The control will cycle through all selected outputs until the high and low pressure switch contacts are opened. If the pressure switch contacts open during the ON TIME, the output will complete the active ON cycle. The next time the high pressure switch is closed the next output in the sequence is fired. Pressure monitoring with no hysteresis is achieved by using only a high pressure switch. Placing a jumper across the high pressure input forces the control to run continuously.

DNC-T2010-020数据文档
型号 品牌 下载
DNC-T2010-020

黑金刚

下载
DNC-4796

BUD

下载
DNC-T2032-R20

黑金刚

下载
DNC-T2020-R20

黑金刚

下载
DNC-T2032-020

黑金刚

下载
DNC-T2610-020

黑金刚

下载

锐单商城 - 一站式电子元器件采购平台