SN55HVD251

SN55HVD251概述

工业 CAN 收发器

The HVD251 is intended for use in applications employing the Controller Area Network CAN serial communication physical layer in accordance with the ISO 11898 Standard. The HVD251 provides differential transmit capability to the bus and differential receive capability to a CAN controller at speeds up to 1 megabits per second Mbps.

Designed for operation in harsh environments, the device features cross-wire, overvoltage and loss of ground protection to ±36 V. Also featured are overtemperature protection as well as –7-V to 12-V common-mode range, and tolerance to transients of ±200 V. The transceiver interfaces the single-ended CAN controller with the differential CAN bus found in industrial, building automation, and automotive applications.

Rs, pin 8, selects one of three different modes of operation: high-speed, slope control, or low-power mode. The high-speed mode of operation is selected by connecting pin 8 to ground, allowing the transmitter output transistors to switch as fast as possible with no limitation on the rise and fall slope. The rise and fall slope can be adjusted by connecting a resistor to ground at pin 8; the slope is proportional to the pin’s output current. Slope control with an external resistor value of 10 kΩ gives about 15-V / µs slew rate; 100 kΩ gives about 2-V/µs slew rate.

If a high logic level is applied to the Rs pin 8, the device enters a low-current standby mode where the driver is switched off and the receiver remains active. The local protocol controller returns the device to the normal mode when it transmits to the bus.

.
Drop-In Improved Replacement for the

PCA82C250 and PCA82C251

.
Bus-Fault Protection of ±36 V
.
Meets or Exceeds ISO 11898
.
Signaling Rates1 up to 1 Mbps
.
High Input Impedance Allows up to 120 Nodes

on a Bus

.
Bus Pin ESD Protection Exceeds 14 kV HBM
.
Unpowered Node Does Not Disturb the Bus
.
Low-Current Standby Mode: 200-µA Typical
.
Thermal Shutdown Protection
.
Glitch-Free Power-Up and Power-Down CAN Bus

Protection for Hot-Plugging

.
DeviceNet Vendor ID #806
.
APPLICA ONS
.
CAN Data Buses
.
Industrial Automation
.
SAE J1939 Standard Data Bus Interface
.
NMEA 2000 Standard Data Bus Interface

1 The signaling rate of a line is the number of voltage transitions that are made per second expressed in bps bits per second.

All other trademarks are the property of their respective owners

SN55HVD251数据文档
型号 品牌 下载
SN55HVD251

TI 德州仪器

下载
SN55453BJG

TI 德州仪器

下载
SN55454BJG

TI 德州仪器

下载
SN55451BJG

TI 德州仪器

下载
SN55452BJG

TI 德州仪器

下载
SN55HVD251DRJR

TI 德州仪器

下载
SN55LBC180RSAR

TI 德州仪器

下载
SN55LBC180RSAT

TI 德州仪器

下载
SN55188J

TI 德州仪器

下载
SN55116J

TI 德州仪器

下载
SN55V

Apex Microtechnology

下载

 锐单商城 - 一站式电子元器件采购平台  

 深圳锐单电子有限公司